Nâng cấp xử lý nước thải 2
Upgrade Waste Water Treatment 2
Solution 2: IONEX KA or KB
Self regenerating circuit version
- closed loop water circuit → no need for fresh water or connection to canalisation!
- Removal of solids and all heavy metals → waste water regulations can be met!
- Decrease of chemical oxygen demand
- For post treatment of etch and galvanic rinse water
- Lower and upper sump level control switch
- 2 different standard sizes
- Special solutions on request
- Machine is connected to etch-, developer- or PTH-machine
- Waste water from these plants is collected in the IONEX
- Tank capacity: max. 110 l (max. 220 l IONEX B)
- Cleaning capacity: approx. 100 (200 IONEX B) Eurocards or 1000 (2000 IONEX B ) prerinsed Eurocards
- Water throughput: 10 l/h (15 l/h IONEX B)
- Consumption of neutralizing agent:: approx. 100ml on 100l waste water
- 4 cleaning steps:
- coarse filter
- active coal micro filter
- 1 cation exchanger columns to remove heavy metal ions
- 2 anion exchanger columns for neutralisation
- Regenerated rinsing water flows into the tank of the pressure unit and is pumped back to the rinsing zones of the tank